Photovoltaic industry drives rapid development of air jet sieve
A large number of particle size distribution detection equipment such as AIR-200 Air Jet Sieve is needed to ensure the particle size of ...
The test report shall include the following particulars:
a) the reference of the method used;
b) the results and the method of expression used;
c) any unsual features noted during the determination;
d ...
♦ The untamped density of aluminium oxide is given by the formula m2-m0/m1-m0
where
—m0 is the mass, in grams of the empty cylindrical container
—m1 is the mass, in grams of the cylindrical container ...
♦ Set the cylindrical container on a flat base.
♦ Adjust the funnel so that its axis coincides approximately with that of the cylinder, with the tip of the funnel at a height of 10 cm above the cylind ...
♦ Determination of the mass of a known volume of aluminium oxide collected after allowing it to fall freely into a stationary container, avoiding vibration.
♦ Expression of the untamped density by div ...